General Physical Properties | ||||||
---|---|---|---|---|---|---|
Property | Test Method | Unit | Typical Value | |||
Nominal Density | (EN ISO 845) / (ASTM D 1622) | Kg/m3 | 37 | 60 | 80 | 120 |
Thermal Conductivity | (EN 12667) / (ASTM C 518) | W/m⋅K | 0.021 | 0.029 | 0.03 | 0.032 |
Colour | Grey | Grey | Grey | Grey | ||
Operating Temperature Limits | Upper Limit / Lower Limit | °C / ºC | 120 /-180 | 120 /-180 | 120 /-180 | 120 / -180 |
Minimum Compressive Strength at +23°C | (EN 826) / (ASTM D 1621) Parallel / Perpendicular | kPa / kPa | 150 / 100 | 320 / 170 | 590 / 440 | 1000 / 800 |
Fire Test Specifi cations | |||||
---|---|---|---|---|---|
Fire Test | Test Method | Specifi cation | |||
Fire Propagation | BS 476-6: 1989 | ||||
Surface Spread of Flame | BS 476-7: 1997 | Class 1* | Class 1* | Class 1* | Class 1* |
Vertical Burning | DIN 4102-1: 1998 | B2 | B2 | B2 | B2 |
Index of Performance (l) not exceeding 12 and sub index (i1) not exceeding 6*
These test results combined enable a Class 0 classification to the Building Regulations in England & Wales. Northern Ireland and the Republic of Ireland, and a Low Risk classification to the Building Standards in Scotland. These tests were conducted on samples of 25mm/1” thickness faced with a reinforced aluminium foil vapour barrier jacket.